Problem Note 61826: JMP® Clinical 6.1 Hotfix for Findings Reports
![]() | ![]() | ![]() | ![]() | ![]() |
This hotfix addresses a variety of issues with Findings Reports in JMP® Clinical 6.1
The first resolved issue is that Action Buttons are not enabled in Findings Distribution. This error occurs when running the following steps.
1) Run a Findings Distribution on data for LB domain
2) Go to the Missing Test Details section of report
3) Select subject counts in the summary table
4) Notice the action buttons for subject level actions do not enable as mentioned in the text above the summary table
The second issue that is resolved is when opening a saved review fails to load with this error:
An error occurred while including reviewReplay.jsl for this report in the saved review.
This bug occurs whenever there is a Findings Distribution report that contains failure of ANOVA model for low occurring findings.
The final issue is sometimes Findings ANOVA shows "&TEAEText" under LB Results
Operating System and Release Information
Product Family | Product | System | Product Release | SAS Release | ||
Reported | Fixed* | Reported | Fixed* | |||
JMP Software | JMP Clinical | Microsoft Windows 10 | 6.1 | 7.0 | 9.4 TS1M4 | 9.4 TS1M5 |
Windows 7 Enterprise 32 bit | 6.1 | 7.0 | 9.4 TS1M4 | 9.4 TS1M5 | ||
Windows 7 Enterprise x64 | 6.1 | 7.0 | 9.4 TS1M4 | 9.4 TS1M5 | ||
Windows 7 Home Premium 32 bit | 6.1 | 7.0 | 9.4 TS1M4 | 9.4 TS1M5 | ||
Windows 7 Home Premium x64 | 6.1 | 7.0 | 9.4 TS1M4 | 9.4 TS1M5 | ||
Windows 7 Professional 32 bit | 6.1 | 7.0 | 9.4 TS1M4 | 9.4 TS1M5 | ||
Windows 7 Professional x64 | 6.1 | 7.0 | 9.4 TS1M4 | 9.4 TS1M5 | ||
Windows 7 Ultimate 32 bit | 6.1 | 7.0 | 9.4 TS1M4 | 9.4 TS1M5 | ||
Windows 7 Ultimate x64 | 6.1 | 7.0 | 9.4 TS1M4 | 9.4 TS1M5 |
A fix for this issue for JMP Clinical 6.1 is available at:
https://tshf.sas.com/techsup/download/hotfix/HF2/A6M.html#61826Type: | Problem Note |
Priority: | medium |
Date Modified: | 2018-02-12 13:09:58 |
Date Created: | 2018-02-09 11:17:31 |